TRH-L-F measuring medium : liquid, gas

The float flowmeter is a volume flow meter that is measured by a float in a vertical conical tube as the flow rate changes, changing the flow area between them, and is also called a rotameter. In the United States and Japan, it is often called a Variable Area Flowmeter or an area flow meter. The principle of the float flowmeter was conceived in the 1860s and appeared in the early 20th century. In terms of the proportion of the number of applications, the floating flowmeter in 17,000 flow meters of 72 companies in the 1985 British sample survey accounted for 19.2%. The output of China's float flowmeter is estimated to be between 150,000 and 170,000 units in 1996, of which about 95% is a glass tube float flowmeter.

The transparent conical tube 4 is most commonly used by borosilicate glass, and is accustomed to the glass tube float flowmeter. The flow indexing is directly engraved on the outer wall of the cone tube 4, and an indexing scale is additionally installed beside the cone tube. The inner cavity of the cone has a smooth surface of the cone and a guiding rib (or plane). The float moves freely within the cone tube, or moves under the guidance of the ribs of the cone tube, and the instrument for guiding the inner wall of the larger smooth surface is also guided by the guide rod.

Right angle type installation metal pipe float flowmeter typical structure, usually suitable for instruments with a diameter of 15-40mm or more. The cone 5 and the float 4 constitute a flow detecting element. The sleeve (not shown in Fig. 3) has an extension portion of the guide rod 3, and the displacement of the float is transmitted to the conversion portion outside the sleeve by means of magnetic steel coupling or the like. The conversion part has two types of local indication and remote transmission signal output. In addition to the right-angle installation structure, there is a straight-through structure concentric with the inlet and outlet lines and the cone tube, which is usually used for instruments with a diameter of less than 10-15 mm.

easuring range: water (20 ° C) 1-200000 l / h

Air (20 ° C, 0.1013 MPa) 0.03-4000 m3 / h

See flow meter, special flow can be customized

Range ratio: standard type 10:1 special type 20:1

Accuracy ] : Standard Type 1.5 Special Type 1.0

Pressure rating: Standard type: DN15-DN50 4.0MPa DN80-DN200 1.6MPa

Special type: DN15-DN50 25MPa DN80-DN200 16MPa

The pressure rating of the jacket is 1.6MPa

Special models should be negotiated with the factory before selection and ordering

Pressure loss: 7kPa-70kPa

Medium temperature: Standard type: -80 °C - +200 °C: PTFE: 0 °C - 85 °C

High temperature type: up to 400 ° C

Medium viscosity: DN15: <5mPa.s (F15.1-F15.3)

<30mPa.s (F15.4-F15.8)

DN25: <250mPFa.s

DN50-DN150: <300mPa.s

Ambient temperature: liquid crystal type -30°C-+85°C

Pointer type -40 ° C - + 120 ° C

Connection form: standard type: DIN2501 standard flange

Special type: any standard flange or thread specified by the user

Cable interface: M20*1.5

Power supply: Standard type: 24VDC two-wire system 4-20mA (10.8VDC-36VDC)

Alarm output: upper or lower limit instantaneous flow alarm, open collector output (maximum 100mA@30VDC internal impedance 100 ohms)

Relay output (contact capacity 1A@30VDC or 0.25A@250VAC or 0.5A@125VAC)

Pulse output: cumulative pulse output with a minimum interval of 50 ms

LCD display: instantaneous flow display value range: 0-50000

Cumulative flow display value range: 0-99999999 (with decimal point)

Protection level: IP65

Explosion-proof mark: intrinsic safety type iaIICT5; flameproof type dIIBT6