Global contact phone number

86-13924563550 Email:306224881@qq.com

TRH-P-210 anti-corrosion pressure sensor / transmitter (high corrosive, strong acid medium pressure measurement and control instrument)

Corrosion-resistant material, anti-corrosion and anti-alkali special pressure sensor-transmitter Strong Acid Chemical Liquid Pressure Sensor - Anti-corrosion Pressure Sensor - Anti-corrosion Pressure TransmitterStrong corrosive medium pressure sensor, anti-corrosion pressure sensor, anti-corrosion pressure transmitterSpecial pump for sewage pump sewage, anti-corrosion pressure sensor

  • Select a product or scenario overview: TRH-P-210 anti-corrosion pressure sensor / transmitter (high corrosive, strong acid medium pressure measurement and control instrument)

TRH-P-210 anti-corrosion pressure sensor / transmitter (high corrosive, strong acid medium pressure measurement and control instrument)

Corrosion-resistant material, anti-corrosion and anti-alkali special pressure sensor-transmitter

Strong Acid Chemical Liquid Pressure Sensor - Anti-corrosion Pressure Sensor - Anti-corrosion Pressure Transmitter

Strong corrosive medium pressure sensor, anti-corrosion pressure sensor, anti-corrosion pressure transmitter

Special pump for sewage pump sewage, anti-corrosion pressure sensor


Honghuayu anti-corrosion pressure sensor / transmitter has the following characteristics:

1: Ceramic piezoresistive chip / corrosion resistant core.

2: The shell is made of polysulphur ethylene.

3: Adopt independent research and development of interference circuits.

4: High polymer high density material with corrosion resistant cable

High-polymer high-density material with ceramic piezoresistive chip, strong acid and alkali resistance, anti-corrosion cable, no abnormality in the test of immersion in 37% HCL hydrochloric acid for two years, mainly used for chlorine disinfection, chemical and battery equipment for tap water disinfection


The medium is a strong corrosive industry such as strong acid and alkali, and pressure measurement and control in food hygiene and medical industries.

 

Range: 0~10(MPa)

Comprehensive accuracy: 0.2% FS, 0.5% FS, 1.0% FS

Output signal: 4~20mA (two-wire system), 0~5V, 1~5V, 0~10V (three-wire system)

Supply voltage: 24DCV (9 ~ 36DCV)

Medium temperature: -20 ~ 85 ° C

Ambient temperature: normal temperature (-20 ~ 85 ° C)

Load resistance: Current output type: maximum 800Ω; voltage output type: greater than 50KΩ

Insulation resistance: greater than 2000MΩ (100VDC

Sealing level: IP65

Long-term stability: 0.1% FS / year

Vibration effect: The output changes less than 0.1% FS within the mechanical vibration frequency of 20Hz~1000Hz.

Electrical interface (signal interface): tight wire nut

Mechanical connection (threaded interface): M16×1.5, M20×1.5, M22×1.5, etc. Other threads can be designed according to customer requirements